Experimental Study for Effect of Perforation in Circular Ring on Thermohydraulic Performance in Circular Cylindrical Tube Heat Exchanger



    Lokesh Pandey1, Sunil Chamoli2 and Alok Kumar3
    1Department of Mechanical Engineering, DIET, Rishikesh,Uttarakhand, India
    2Department of Mechanical Engineering, DIT University, Dehradun-248009,Uttarakhand, India
    3Department of Mechanical Engineering, Tulas Institute, Dehradun-248009,Uttarakhand, India


    Abstract

    The present work focuses on effect of perforated circular ring insert (PCRI) on thermal performance of a circular tube. Different geometrical and flow parameters used in the present study includes fixed diameter ratio (“d/D” ratio) = 0.7, pitch ratio (“l/D” ratio)= 1,2 & 3, Perforation index (“Pa/Ta” ratio) = 0%, 8%, 16% & 24%, and Reynolds number(Re) between 6,500 to 23,000 respectively. The experimentation is carried out in a test section of 1.4 m length and 68 mm hydraulic diameter. The Nusselt number enhancement of the order of 4 times to plain tube is found for Pitch ratio=1 and Perforation index = 0%, while the thermal performance of order of 1.25 is accorded for Pitch ratio=1 and Perforation index of 24%.


 